# Signing key and mail password committed in appsettings **Location:** `src/PatientPortal.Api/appsettings.json`, the `Jwt:Key` and `Mail:Password` values (configuration used across the app). The JWT signing key and the outbound mail password are written as literal values in the committed configuration file. Anyone with read access to the source, including everyone who can see the repository, has both secrets. With the signing key an attacker can forge a valid token for any user and any role, bypassing authentication entirely; the mail credentials allow sending mail as the clinic. Committed secrets also persist in history after any later rotation.